Answer:
Heat of the reservoir is 461.38 K or 188.1 °C
The heating load is 18.705 kW
Explanation:
COP = 8.7
working temperature [tex]T_{h}[/tex] = 248 °C = 248 + 273.3 = 521.3 K
work power W = 2.15 kW
reservoir temperature [tex]T_{c}[/tex] = ?
heating load Q = ?
We know that
COP = Q/W
Q = COP x W = 8.7 x 2.15 = 18.705 kW
Also,
COP = [tex]\frac{T_{h} }{T_{h}- T_{c} }[/tex] = [tex]\frac{521.3}{521.3- T_{c} }[/tex]
8.7 = [tex]\frac{521.3}{521.3- T_{c} }[/tex]
4535.31 - 8.7[tex]T_{c}[/tex] = 521.3
4535.31 - 521.3 = 8.7[tex]T_{c}[/tex]
4014.01 = 8.7[tex]T_{c}[/tex]
[tex]T_{c}[/tex] = 4014.01/8.7 = 461.38 K
or 461.38 -273.3 = 188.1 °C