A heat pump operates on a Carnot heat pump cycle with a COP of 8.7. It keeps a space at 248C by consum-ing 2.15 kW of power. Determine the temperature of the reservoir from which the heat is absorbed and the heat-ing load provided by the heat pump.

Respuesta :

Answer:

Heat of the reservoir is 461.38 K or 188.1 °C

The heating load is 18.705 kW

Explanation:

COP = 8.7

working temperature [tex]T_{h}[/tex] = 248 °C = 248 + 273.3 = 521.3 K

work power W = 2.15 kW

reservoir temperature [tex]T_{c}[/tex] = ?

heating load Q = ?

We know that

COP = Q/W

Q = COP x W = 8.7 x 2.15 = 18.705 kW

Also,

COP = [tex]\frac{T_{h} }{T_{h}- T_{c} }[/tex] = [tex]\frac{521.3}{521.3- T_{c} }[/tex]

8.7 = [tex]\frac{521.3}{521.3- T_{c} }[/tex]

4535.31 - 8.7[tex]T_{c}[/tex]  = 521.3

4535.31 - 521.3 = 8.7[tex]T_{c}[/tex]  

4014.01 = 8.7[tex]T_{c}[/tex]  

[tex]T_{c}[/tex]  = 4014.01/8.7 = 461.38 K

or 461.38 -273.3 = 188.1 °C