Answer:
The temperature difference between the tube temperature and compressed air temperature of 457.979 K is very large which can impact on the accuracy of the humidity measurement such as error magnification and sensitivity to rapid changes
Explanation:
For isentropic compression, we have;
[tex]\frac{p_{1}}{p_{2}} = \left [\frac{T_{1}}{T_{2}} \right ]^{\frac{\gamma}{\gamma -1}}[/tex]
Where:
p₁ = Initial pressure = 14.5 psia
p₂ = Final pressure = 500 psia
T₁ = Initial temperature = 80 °F = 299.8167 K
T₂ = Final temperature (Required)
Tube temperature = 200 °F = 366.4833 K
γ = The ratio of the specific heats of the gas, cp/cv = 1.4 for air.
Plugging in the values we have;
[tex]\frac{14.5}{500} = \left [\frac{299.8167}{T_2 } \right ]^{\frac{1.4}{1.4 -1}}[/tex]
[tex]\left [\frac{299.8167}{T_2 } \right ]= 0.364[/tex]
T₂ =824 K
Therefore, the temperature difference between the tube temperature and compressed air temperature which is 824.46 K - 366.48 K = 457.979 K is very large which can impact on the accuracy of the humidity measurement such as error magnification and sensitivity to rapid changes.