Answer:
Explanation:
Hold time is referred as the minimum time after active edge of clock after which data must be stable so hold violation will cause the incorrect data to be added.
In such circuit the first thing that can be done to fix this will be :
- Reset the clock to the start/endpoint to make end point clock arrive earlier.
- Insert a buffer chain to increase the propagation time.
- Add delays