A generator produces 60 A of current at 120 V. The voltage is usually stepped up to 4500 V by a transformer and transmitted through a power line of total resistance 1.0 Ω. Find the percentage power lost in the transmission line if the voltage is not stepped up.

Respuesta :

Answer:

The percentage power lost in the transmission line if the voltage not stepped up is 50%.

Explanation:

Given that,

Current = 60 A

Voltage = 120 V

Resistance = 1.0 ohm

We need to calculate the power

Using formula of power

[tex]P=I\times V[/tex]

Where,I =current

V = voltage

Put the value into the formula

[tex]P=60\times120[/tex]

[tex]P=7200\ W[/tex]

We need to calculate the percentage power lost in the transmission line

If the voltage is not stepped up

Then, the power loss

[tex]P'=I^2\times R[/tex]

Put the value into the formula

[tex]P'=(60)^2\times1[/tex]

[tex]P'=3600\ W[/tex]

The percentage power loss P''

[tex]P''=\dfrac{P'}{P}\times100=\dfrac{3600}{7200}\times100[/tex]

[tex]P''=50\%[/tex]

Hence, The percentage power lost in the transmission line if the voltage not stepped up is 50%.