15.5 A natural gas–fi red, stationary gas-turbine engine is used for electrical power generation. The exhaust emission level of nitric oxide is 20 ppm (by vol.), measured in the exhaust with an oxygen concentration of 13 percent (by vol.). No aftertreatment (SNCR or SCR) is used. A. What is the nitric oxide concentration corrected to 3 percent oxygen?